• HV510 series high-performance frequency converters
  • HV510 series high-performance frequency converters
  • HV510 series high-performance frequency converters
HV510 series high-performance frequency converters
discuss personally
Model
HV510/380V
Basic info
Brand RW Energy
Model NO. HV510 series high-performance frequency converters
Rated frequency 50/60Hz
Series HV
Product Detail

Overview

HV510 series frequency converter is a new generation of high-performance vector frequency converter of Hewang Electric, using a new high-performance open and closed loop vector control technology, supporting asynchronous motor and permanent magnet synchronous motor drive control; The high-quality, powerful performance and high-power density design enhance the advantages of ease of use, reliability, environmental adaptability, functional diversity, application flexibility in industrial applications, improve design standards and optimize installation space, etc., and upgrade the user experience in many aspects. It is widely used in metallurgy, lifting, petroleum, machine tools, plastics, metal products, papermaking, textile, printing and packaging and other automatic production equipment to drive.

Performance characteristics

Safe and reliable

  • Innovative independent air duct design

  • Efficient and accurate thermal simulation design

  • Rigorous temperature rise test and factory load aging

  • Automatic spraying process of conformal paint

  • Perfect fault protection function

High adaptability

  •  Wide grid adaptation design, -15%~+10%

  • Built-in C3 filter

  • EMC ground break design

  • Built-in brake unit design

  • Refined book-type design

Advanced control technology

  • V/F, open-loop vector, closed-loop vector control

  • Support drive asynchronous motor, permanent magnet synchronous motor

  • Support motor speed and torque mode control

  • Support two sets of motor parameter switching control

Excellent performance

  • Rich and comprehensive motor parameter self-identification ability

  • Perfect braking ability, support DC braking, energy consumption braking

  • Support various mainstream communication protocols: Profibus-DP, Profinet, etc.

  • Diversified expansion capabilities, I/O terminal cards, communication cards, etc

Featured app features

  • Output frequency up to 1500Hz

  •  Master-slave synchronous control function

  • Power failure restart function

  • Zero servo function

  • Swing frequency function

  • Encoder redundancy function

Autonomous and rapid commissioning

  • Background quick debugging software is available • Support frequency converter event recording and 12-channel oscilloscope recording

  • Support parameter editing, status monitoring, fault data and waveform download

Main parameters

project

Specifications and technical data

Input voltage

380V (-15%)~480V (+10%) three-phase

Input power frequency

50Hz/60Hz ±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0Hz~1500Hz

Motor type

Asynchronous motor, permanent magnet synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:100 V/F; 1:200 OLVC; 1:1000 CLVC

Start torque

VF:100%(0.5Hz);OLVC:150%(0.25Hz);CLVC:200%(0Hz)

Torque accuracy

±5% (OLVC, 5Hz and above), ±3% (CLVC)

Torque pulsation

≤±5%, under vector control mode

Steady speed accuracy

OLVC: 0.2%; CLVC :0.01%

Torque response

≤5ms, under vector control

acceleration and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150% 1min/5min, 200% 3s/5min for heavy duty applications; Light load application 110% 1min/5min, 150% 10s/5min

VF curve

Linear type, multi-point type, V/F semi-separation mode, V/F complete separation mode

Input frequency resolution

Digital setting: 0.01Hz ; Analog setting: Maximum frequency ×0.025%

acceleration and deceleration curves

linear and S-curve acceleration and deceleration mode; Four acceleration and deceleration times, one emergency stop deceleration time

Jogging control

In some applications, the frequency converter needs to run at low speed for a short period of time to facilitate testing the condition of the equipment

Torque control

Torque control is possible when vector controlled

Simple PLC, multi-terminal speed

16 speed operation is achieved through the control terminal

Built-in PID

It can be easily formed as a closed-loop control system

Virtual IO

8 virtual VDI/VDO and 3 AI DI for simple logic control

Overvoltage and overcurrent stall control

Automatic current and voltage limit during operation to prevent frequent overcurrent and overvoltage tripping

DC braking

Start the DC brake and stop the DC brake

Pre-excitation

The motor is pre-excited when the frequency converter is started, and the magnetic field is established inside the motor, which can effectively improve the torque characteristics during the start of the motor

Overexcitation

It can effectively suppress the rise of bus voltage during the deceleration process, avoid frequent overvoltage faults, and realize rapid braking to meet the rapid stop of power outages

RPM tracking

Both asynchronous and synchronous machines support speed tracking function; Vector control and V/F control both support speed tracking function

Protection function

Overvoltage suppression, undervoltage suppression, V/F overcurrent suppression, ground short circuit protection, phase loss protection, speed deviation detection, overvoltage protection, overcurrent protection, undervoltage protection, overload protection, overtemperature protection, start protection, bus undervoltage point setting, bus overvoltage point setting, etc

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!